E12: normal temperature water flow alarm
Hanli · Hanli Hanli HL-1000 to HL-30000 / SCH fiber laser chiller (dual circuit)
What it means
Head-circuit flow low (blockage, reversed hoses, leak or flow switch)
Can I keep running?
KB severity: Machine down
The knowledge base lists this as a machine-down fault. Stop the job and do not keep running until a technician has checked the machine.
The knowledge base records some owner-level checks for this fault. That is not a repair procedure from Kerfwise.
Where it points in the machine
cooling (flow switch)
Source: Stevis Tech (seller), fault code table (publisher text only)
Source: Hanli, Hanli user manual alarm table
Source: Stevis Tech (seller), fault code table (publisher text only)
Source: Hanli, Hanli user manual alarm table
Related codes on this system
- E01 — low temperature water probe fault
- E02 — low temperature water high temperature alarm
- E03 — compressor pressure failure
- E04 — phase sequence alarm
- E05 — low temperature water flow alarm
- E06 — water level switch alarm
- E07 — compressor overload
- E08 — low temperature water low temperature alarm
- E09 — normal temperature water probe fault
- E10 — normal temperature water high temperature alarm
- E11 — normal temperature water low temperature alarm
Related symptoms in the knowledge base
- FTC signal wire alarm stops cutting
- CO2 laser tube will not fire although the laser switch is on (Thunder Nova/Mini: causes listed are beam path misalignment, loose PSU or contactor wiring, failed tube or PSU, failed opto-isolator or controller laser signal port)
- Chiller panel reads normal but a red light is on and the buzzer sounds (Thunder Laser AU troubleshooting list)
Do not attempt DIY repair on high-voltage or Class 4 laser equipment. Get a technician. You can request one using the form on this page.