Communication abnormal alarm
Maxphotonics · Maxphotonics Maxphotonics MFMC 12000-15000 (G4) CW fibre laser
What it means
No signal between a single module and the main module
Can I keep running?
KB severity: Machine down
The knowledge base lists this as a machine-down fault. Stop the job and do not keep running until a technician has checked the machine.
The knowledge base records some owner-level checks for this fault. That is not a repair procedure from Kerfwise.
Where it points in the machine
communication (module communication line)
Source: Demark (CN machine maker), 7-Error Listing (publisher text only)
Source: Demark (CN machine maker), 7-Error Listing (publisher text only)
Related codes on this system
Related symptoms in the knowledge base
- Laser module will not move
- FTC signal wire alarm stops cutting
- CO2 laser tube will not fire although the laser switch is on (Thunder Nova/Mini: causes listed are beam path misalignment, loose PSU or contactor wiring, failed tube or PSU, failed opto-isolator or controller laser signal port)
- Chiller panel reads normal but a red light is on and the buzzer sounds (Thunder Laser AU troubleshooting list)
Do not attempt DIY repair on high-voltage or Class 4 laser equipment. Get a technician. You can request one using the form on this page.
Get a tech on it