Desktop
Documented alarm codes with citations — not repair instructions.
- Flame detected — xTool, xTool xTool Creative Space (XCS)
- Air Assist error — xTool, xTool xTool Creative Space (XCS)
- Focus failed — xTool, xTool xTool Creative Space (XCS)
- Lid open — xTool, xTool xTool Creative Space (XCS)
- Connection failed — xTool, xTool xTool Creative Space (XCS)
- M505 S1 — M505 S1 / Flame Alarm — xTool, xTool xTool Creative Space (XCS)
- E10 — E10 / Interlock Open — xTool, xTool xTool Creative Space (XCS)
- Water cooling flow error — xTool, xTool xTool Creative Space (XCS)
- Inkjet module not recognised — xTool, xTool xTool Creative Space (XCS)
- M222 S4 — Device moved — xTool, xTool xTool S1 machine firmware/controller
- M222 S7 — Start processing without a project file or with the lid opened — xTool, xTool xTool S1 machine firmware/controller
- M222 S9 — Flame detected — xTool, xTool xTool S1 machine firmware/controller
- M222 S20 — The device reached position limits during processing — xTool, xTool xTool S1 machine firmware/controller
- M222 S21 — Communication exceptions between the Wi-Fi module and the main controller — xTool, xTool xTool S1 machine firmware/controller
- M222 S22 — Communication exceptions between the laser module and the main controller — xTool, xTool xTool S1 machine firmware/controller
- M363 S0 — Distance measurement exceptions. — xTool, xTool xTool S1 machine firmware/controller
- M363 S2 — Distance sensor signal exceptions. — xTool, xTool xTool S1 machine firmware/controller
- M363 S3 — The distance sensor has not been reset. — xTool, xTool xTool S1 machine firmware/controller
- M363 S4 — Distance measurement exceptions. — xTool, xTool xTool S1 machine firmware/controller
- M363 S5 — Distance measurement exceptions. — xTool, xTool xTool S1 machine firmware/controller
- M53 T0 — SD card exceptions or failure — xTool, xTool xTool S1 machine firmware/controller
- M53 T0 — The flash storage encounters an exception or is damaged — xTool, xTool xTool S1 machine firmware/controller
- M53 C1/C2/W2 — Baseplate or riser base exception — xTool, xTool xTool S1 machine firmware/controller
- M53 I0 — Light interference detected — xTool, xTool xTool S1 machine firmware/controller
- M53 S0 — Access-control key removed — xTool, xTool xTool S1 machine firmware/controller
- M53 W0 — Laser module overtemperature — xTool, xTool xTool S1 machine firmware/controller
- M53 F5 — Flame risk detected — xTool, xTool xTool S1 machine firmware/controller
- M8 — Motor driver chip errors — xTool, xTool xTool S1 machine firmware/controller
- M53 L1 — Cleaning the laser module — xTool, xTool xTool S1 machine firmware/controller
- Qx14 1 — X-Axis Homing Failed — xTool, xTool xTool M1 machine firmware/controller
- Qx14 2 — Y-Axis Homing Failed — xTool, xTool xTool M1 machine firmware/controller
- Qx14 3 — Z-Axis Homing Failed — xTool, xTool xTool M1 machine firmware/controller
- Qx14 4 — X-Axis Motor Driver Exception — xTool, xTool xTool M1 machine firmware/controller
- Qx14 5 — Y-Axis Motor Driver Exception — xTool, xTool xTool M1 machine firmware/controller
- Qx14 6 — Z-Axis Motor Driver Exception — xTool, xTool xTool M1 machine firmware/controller
- Qx14 7 — U-Axis Motor Driver Exception — xTool, xTool xTool M1 machine firmware/controller
- Qx21 1 — Laser Module Not Working — xTool, xTool xTool M1 machine firmware/controller
- Wx 13 — Cleaning the Laser Module — xTool, xTool xTool M1 machine firmware/controller
- Board communication failure — xTool, xTool xTool M1 Ultra machine firmware/controller
- Chip exceptions on the Z-axis control board — xTool, xTool xTool M1 Ultra machine firmware/controller
- Main control board temperature exception — xTool, xTool xTool M1 Ultra machine firmware/controller
- M23 S135 — X-axis driver exception — xTool, xTool xTool M1 Ultra machine firmware/controller
- M23 S136 — Y-axis Driver Exception — xTool, xTool xTool M1 Ultra machine firmware/controller
- M23 S137 — Z-axis driver exception (Module on basic carriage) — xTool, xTool xTool M1 Ultra machine firmware/controller
- M23 S155 — Z-axis driver exception (Module on multi-function holder) — xTool, xTool xTool M1 Ultra machine firmware/controller
- M23 S138 — U-axis driver exception — xTool, xTool xTool M1 Ultra machine firmware/controller
- Z-axis driver exception — xTool, xTool xTool P2 machine firmware/controller
- U-axis driver exception — xTool, xTool xTool P2 machine firmware/controller
- Safety lock locking exception — xTool, xTool xTool P2 machine firmware/controller
- Safety lock unlocking exception — xTool, xTool xTool P2 machine firmware/controller
- Fan current too low — xTool, xTool xTool P2 machine firmware/controller
- Fan current too high — xTool, xTool xTool P2 machine firmware/controller
- X-Axis Homing Failure — xTool, xTool xTool P2 machine firmware/controller
- Y-Axis Homing Failure — xTool, xTool xTool P2 machine firmware/controller
- Z-Axis Homing Failure — xTool, xTool xTool P2 machine firmware/controller
- Water tank flow too low — xTool, xTool xTool P2 machine firmware/controller
- Water-cooled fan exception — xTool, xTool xTool P2 machine firmware/controller
- Air pump current exception — xTool, xTool xTool P2 machine firmware/controller
- Board Communication Failure — xTool, xTool xTool P2 machine firmware/controller
- H — Liquid temperature alarm: Temperature too high — xTool, xTool xTool P2 machine firmware/controller
- L — Liquid temperature alarm: Temperature too low — xTool, xTool xTool P2 machine firmware/controller
- Exceptions occur (solid red ring, fault indicator lit) — xTool, xTool xTool P2 machine firmware/controller
- Water tank temperature too high — xTool, xTool xTool P2S machine firmware/controller
- Fan current too high — xTool, xTool xTool P2S machine firmware/controller
- SMOKING_FAN.CUR_LOW. — Fan current too low — xTool, xTool xTool P2S machine firmware/controller
- SMOKING_FAN.CUR_ABNORMAL.NOT_FOUND — Fan exceptions — xTool, xTool xTool P2S machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.CUR_HIGH — Air pump current exception — xTool, xTool xTool P2S machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.CUR_LOW — Air pump current exception — xTool, xTool xTool P2S machine firmware/controller
- AIRPUMP.ELEMENT_NOT_FOUND — Air pump current exception — xTool, xTool xTool P2S machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.TMEP_HIGH — Air pump current exception — xTool, xTool xTool P2S machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.STALLED — Air pump current exception — xTool, xTool xTool P2S machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.FIRST_PEAK_CUR_PROTECT — Air pump current exception — xTool, xTool xTool P2S machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.SECOND_PEAK_CUR_PROTECT — Air pump current exception — xTool, xTool xTool P2S machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.UPPER_MOS_ERR — Air pump current exception — xTool, xTool xTool P2S machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.CUR_OVER — Air pump current exception — xTool, xTool xTool P2S machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.VOLTAGE_HIGH — Air pump current exception — xTool, xTool xTool P2S machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.NTC_SHORT_CIRCUIT — Air pump current exception — xTool, xTool xTool P2S machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.SPEED_OVER — Air pump current exception — xTool, xTool xTool P2S machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.PHASE_LACK — Air pump current exception — xTool, xTool xTool P2S machine firmware/controller
- BOARDS.ELEMENT_NOT_FOUND.motion_gd470 — Main control board is disconnected — xTool, xTool xTool P3 machine firmware/controller
- BOARDS.ELEMENT_NOT_FOUND.airpump_gd303 — Main control board is disconnected — xTool, xTool xTool P3 machine firmware/controller
- BOARDS.ELEMENT_NOT_FOUND.z_axis_gd303 — Main control board is disconnected — xTool, xTool xTool P3 machine firmware/controller
- BOARDS.ELEMENT_NOT_FOUND.display_gd757 — Main control board is disconnected — xTool, xTool xTool P3 machine firmware/controller
- CONTROLLER.TMP_HIGH.MASTER — Main controller temperature is too high — xTool, xTool xTool P3 machine firmware/controller
- GO_HOME.FAILED.X_AXIS — Gantry homing exception — xTool, xTool xTool P3 machine firmware/controller
- GO_HOME.FAILED.Y_AXIS — Gantry homing exception — xTool, xTool xTool P3 machine firmware/controller
- GO_HOME.FAILED.Z_AXIS — Gantry homing exception — xTool, xTool xTool P3 machine firmware/controller
- GO_HOME.FAILED.V_AXIS — Gantry homing exception — xTool, xTool xTool P3 machine firmware/controller
- MOTOR_DRIVER.ELEMENT_ABNORMAL.X_AXIS — Motor driver exception — xTool, xTool xTool P3 machine firmware/controller
- MOTOR_DRIVER.ELEMENT_ABNORMAL.Y_AXIS_L — Motor driver exception — xTool, xTool xTool P3 machine firmware/controller
- MOTOR_DRIVER.ELEMENT_ABNORMAL.Y_AXIS_R — Motor driver exception — xTool, xTool xTool P3 machine firmware/controller
- MOTOR_DRIVER.ELEMENT_ABNORMAL.Z_AXIS — Motor driver exception — xTool, xTool xTool P3 machine firmware/controller
- MOTOR_DRIVER.ELEMENT_ABNORMAL.V_AXIS_RD — Motor driver exception — xTool, xTool xTool P3 machine firmware/controller
- MOTOR_DRIVER.ELEMENT_ABNORMAL.V_AXIS_RU — Motor driver exception — xTool, xTool xTool P3 machine firmware/controller
- MOTOR_DRIVER.ELEMENT_ABNORMAL.V_AXIS_LU — Motor driver exception — xTool, xTool xTool P3 machine firmware/controller
- MOTOR_DRIVER.ELEMENT_ABNORMAL.V_AXIS_LD — Motor driver exception — xTool, xTool xTool P3 machine firmware/controller
- MOTOR_DRIVER.ELEMENT_ABNORMAL.U_AXIS_REVOLVE — Motor driver exception — xTool, xTool xTool P3 machine firmware/controller
- MOTOR_DRIVER.ELEMENT_ABNORMAL.U_AXIS_CARRY — Motor driver exception — xTool, xTool xTool P3 machine firmware/controller
- MOTOR_DRIVER.ELEMENT_ABNORMAL.GAS_BOTTLE — Motor driver exception — xTool, xTool xTool P3 machine firmware/controller
- BOTTOM_BED_LIMIT_LEVELING.TIMEOUT — Bed leveling exception — xTool, xTool xTool P3 machine firmware/controller
- BOUBLE_Y_LIMIT_LEVELING.TIMEOUT. — Gantry calibration exception — xTool, xTool xTool P3 machine firmware/controller
- CAMERA.EVENT_TYPE_SIDE_CAMERA_UP_DISCONNECT. — Detected disconnection of the side camera — xTool, xTool xTool P3 machine firmware/controller
- CAMERA.EVENT_TYPE_SIDE_CAMERA_DOWN_DISCONNECT. — Detected disconnection of the side camera — xTool, xTool xTool P3 machine firmware/controller
- COOL_WATER_MACHINE.ELEMENT_ABNORMAL.WATER_TMEP_SENSOR_ERR — Sensor exception detected — xTool, xTool xTool P3 machine firmware/controller
- COOL_WATER_MACHINE.ELEMENT_ABNORMAL.ENV_TMEP_SENSOR_ERR — Sensor exception detected — xTool, xTool xTool P3 machine firmware/controller
- COOL_WATER_MACHINE.ELEMENT_ABNORMAL.NOT_FOUND — Sensor exception detected — xTool, xTool xTool P3 machine firmware/controller
- COOL_WATER_MACHINE.ELEMENT_ABNORMAL.NOT_WORKED — Sensor exception detected — xTool, xTool xTool P3 machine firmware/controller
- COOLWATER_MACHINE.ELEMENT_ABNORMAL.HUMI_ERROR — Sensor exception detected — xTool, xTool xTool P3 machine firmware/controller
- COOL_WATER_MACHINE.ELEMENT_ABNORMAL.WATER_LINE_LOW — Device water level too low — xTool, xTool xTool P3 machine firmware/controller
- COOL_WATER_MACHINE.ELEMENT_ABNORMAL.WATER_FLOW_LOW — Device water flow too low — xTool, xTool xTool P3 machine firmware/controller
- COOL_WATER_MACHINE.TMP_WARNNING.WATER_TEMP_LOW — Device water temperature is slightly below normal — xTool, xTool xTool P3 machine firmware/controller
- COOL_WATER_MACHINE.TMP_ERROR.WATER_TIEMP_ULTRA_LOW — Device water temperature too low — xTool, xTool xTool P3 machine firmware/controller
- COOL_WATER_MACHINE.TMP_WARNNING.WATER_TEMP_HIHG — Device water temperature is slightly above normal — xTool, xTool xTool P3 machine firmware/controller
- COOL_WATER_MACHINE.TMP_ERROR.WATER_TEMP_ULTRA_HIHG — Device water temperature too high — xTool, xTool xTool P3 machine firmware/controller
- COOL_WATER_MACHINE.TMP_ERROR.WATER_TEMP_HIGH_LONG_TIME — Device temperature too high — xTool, xTool xTool P3 machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.STALLED — Air pump exception — xTool, xTool xTool P3 machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.CUR_LOW — Air pump exception — xTool, xTool xTool P3 machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.PUMP_TEMP_HIGH — Air pump exception — xTool, xTool xTool P3 machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.PUMP_TEMP_ERR — Air pump exception — xTool, xTool xTool P3 machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.TEMP_HIGH — Air pump exception — xTool, xTool xTool P3 machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.TEMP_LOW — Air pump exception — xTool, xTool xTool P3 machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.NTC_SHORT_CIRCUIT — Air pump exception — xTool, xTool xTool P3 machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.SECOND_PEAK_CUR_PROTECT — Air pump exception — xTool, xTool xTool P3 machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.FIRST_PEAK_CUR_PROTECT — Air pump exception — xTool, xTool xTool P3 machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.SECOND_OVER_CUR — Air pump exception — xTool, xTool xTool P3 machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.FIRST_OVER_CUR — Air pump exception — xTool, xTool xTool P3 machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.SHORT_CIRCUIT — Air pump exception — xTool, xTool xTool P3 machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.VOLTAGE_HIGH — Air pump exception — xTool, xTool xTool P3 machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.VOLTAGE_LOW — Air pump exception — xTool, xTool xTool P3 machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.SPEED_OVER — Air pump exception — xTool, xTool xTool P3 machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.HALL_EXCEPT_PRE — Air pump exception — xTool, xTool xTool P3 machine firmware/controller
- AIRPUMP.ELEMENT_ABNORMAL.HALL_EXCEPT_RUNNING — Air pump exception — xTool, xTool xTool P3 machine firmware/controller
- LASER_POWER.TMP_HIGH. — Laser power supply temperature too high — xTool, xTool xTool P3 machine firmware/controller
- GYRO_SENSOR.MACHINE_TILTED. — Device tilted — xTool, xTool xTool P3 machine firmware/controller
- WEIGHT_SENSOR.ELEMENT_ABNORMAL. — Fire suppression system exception — xTool, xTool xTool P3 machine firmware/controller
- GAS_BOTTLE_HOME.TIMEOUT — Gas cylinder motor exception — xTool, xTool xTool P3 machine firmware/controller
- FEEDER.SENSOR_DISCONNECT. — Feeding accessory sensor disconnected — xTool, xTool xTool P3 machine firmware/controller
- FEEDER.FAILED.RESET — Feeding accessory homing failed — xTool, xTool xTool P3 machine firmware/controller
- RED_LASER_HEAD.TMP_HIGH — Infrared laser module temperature too high — xTool, xTool xTool P3 machine firmware/controller
- RED_LASER_HEAD.TMP_LOW — Infrared laser module temperature too low — xTool, xTool xTool P3 machine firmware/controller
- No TF card is detected in the device. Please insert the TF card, restart the machine, and try again. — xTool, xTool xTool D1 Pro machine firmware/controller
- The device has been moved. — xTool, xTool xTool D1 Pro machine firmware/controller
- A flame is detected. — xTool, xTool xTool D1 Pro machine firmware/controller
- The laser module has moved over the position limit. — xTool, xTool xTool D1 Pro machine firmware/controller
- FIRE_RECOGNITION — Flame Detected — xTool, xTool xTool F1 machine firmware/controller
- Access-control key — xTool, xTool xTool F1 Ultra machine firmware/controller
- Device moved — xTool, xTool xTool F2 Ultra machine firmware/controller
- Exhaust fan installation abnormal — xTool, xTool xTool F2 Ultra machine firmware/controller
- Access-control key — xTool, xTool xTool F2 Ultra machine firmware/controller
- Flame detected — xTool, xTool xTool F2 Ultra machine firmware/controller
- Isolator Overheating — xTool, xTool xTool F2 Ultra machine firmware/controller
- Access-control key — xTool, xTool xTool F2 Ultra UV machine firmware/controller
- Flame detected — xTool, xTool xTool F2 Ultra UV machine firmware/controller
- Device moved — xTool, xTool xTool F2 Ultra UV machine firmware/controller
- M9039 S4 — Exceptions occur — xTool, xTool xTool AP series air purifier (SafetyPro AP2)
- BOARDS.ELEMENT_NOT_FOUND.wcb_gd330 — Board communication failure — xTool, xTool xTool P2 machine firmware/controller
- BOARDS.ELEMENT_NOT_FOUND.ui_gd330 — Board communication failure — xTool, xTool xTool P2 machine firmware/controller
- BOARDS.ELEMENT_NOT_FOUND.motion_gd450 — Board communication failure — xTool, xTool xTool P2 machine firmware/controller
- Refresh failed — xTool, xTool xTool P2 machine firmware/controller
- Refresh failed — xTool, xTool xTool P2 machine firmware/controller
- Flame detected — xTool, xTool xTool F1 Ultra machine firmware/controller
- ALARM:cancel — Device reported an error — xTool, LightBurn Software LightBurn
- Communication with controller failed — xTool, LightBurn Software LightBurn
- ALARM:1 — Hard limit triggered (err:limitCheck) — xTool, xTool xTool D1 Pro machine firmware/controller
- ERROR:01 — angle data abnormal — Creality Falcon, Creality Creality Falcon2 / Falcon2 Pro control board firmware
- ERROR:02 — no G-code file in TF card root — Creality Falcon, Creality Creality Falcon2 / Falcon2 Pro control board firmware
- ERROR:04 — no airflow detected — Creality Falcon, Creality Creality Falcon2 / Falcon2 Pro control board firmware
- ERROR:05 — flame detected — Creality Falcon, Creality Creality Falcon2 / Falcon2 Pro control board firmware
- ERROR:06 — lens contamination detected — Creality Falcon, Creality Creality Falcon2 / Falcon2 Pro control board firmware
- ERROR:07 — laser module temperature high — Creality Falcon, Creality Creality Falcon2 / Falcon2 Pro control board firmware
- ERROR:08 — module air pressure sensor fault — Creality Falcon, Creality Creality Falcon2 / Falcon2 Pro control board firmware
- ERROR:09 — module flame sensor fault — Creality Falcon, Creality Creality Falcon2 / Falcon2 Pro control board firmware
- ERROR:10 — module lens sensor fault — Creality Falcon, Creality Creality Falcon2 / Falcon2 Pro control board firmware
- ERROR:11 — no LD temperature sensor — Creality Falcon, Creality Creality Falcon2 / Falcon2 Pro control board firmware
- ERROR:12 — LD sensor short circuit — Creality Falcon, Creality Creality Falcon2 / Falcon2 Pro control board firmware
- ERROR:13 — module CPU temperature too high — Creality Falcon, Creality Creality Falcon2 / Falcon2 Pro control board firmware
- ERROR:14 — host CPU temperature too high — Creality Falcon, Creality Creality Falcon2 / Falcon2 Pro control board firmware
- ERROR:24 — machine unsealed — Creality Falcon, Creality Creality Falcon2 / Falcon2 Pro control board firmware
- ERROR:25 — air pump abnormal — Creality Falcon, Creality Creality Falcon2 / Falcon2 Pro control board firmware
- ERROR:01 — angle data abnormal — Creality Falcon, Creality Creality Falcon A1 control firmware
- ERROR:02 — no G-code file in TF card root — Creality Falcon, Creality Creality Falcon A1 control firmware
- ERROR:14 — host CPU temperature too high — Creality Falcon, Creality Creality Falcon A1 control firmware
- ERROR:24 — machine unsealed — Creality Falcon, Creality Creality Falcon A1 control firmware
- ERROR:25 — air pump abnormal — Creality Falcon, Creality Creality Falcon A1 control firmware
- 01001609 — home return failed, limit switch not found — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 01001039 — value out of range — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 01001041 — spindle not running in CSS/sync mode — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 01001043 — maximum feed rate exceeded — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 01001044 — RPM out of range — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 01001046 — zero the machine to proceed — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 01001048 — value conflict in G-code keyword — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 01001051 — motor failure — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 01003304 — alarm service interface timeout — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 01003305 — did not reach target position (log command) — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 01003306 — camera exposure control failed — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 01003307 — focus light spot not detected — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 01003308 — abnormal camera capture — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 01003309 — autofocus unknown exception — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 01003310 — autofocus shield not closed — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 02002201 — module upgrade failed — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 02002201 — file decompression failed — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 04012008 — laser module has no NTC sensor — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 04011001 — lens dirty — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 04012002 — Z-axis flame alarm — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 04011003 — Z-axis air pressure alarm — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 04011004 — Z-axis die temperature too high — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 04011020 — Z-axis infrared module high temperature — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 04031001 — tilt alarm — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 06002007 — WiFi incorrect password — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 06002010 — WiFi connection timed out — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 06002012 — DHCP connection timed out — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 06002022 — SSID temporarily disabled — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 07001001 — flame detected (video) — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 07002002 — camera not detected — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 07002006 — autofocus failed, algorithm abnormal — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 07002007 — autofocus failed, no spot or out of range — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 07002008 — autofocus failed, bad input parameters — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 07002009 — autofocus failed, focus plane out of range — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 07002010 — autofocus failed, algorithm abnormal — Creality Falcon, Creality Creality Falcon A1 Pro control firmware (8-digit fault codes by service group)
- 01001049 04010101 04012101 04020101 04022101 04030101 04032101 04040101 04042101 04050101 04052101 04060101 04062101 04070101 04072101 04080101 04082101 04090101 04092101 04100101 04102101 04110101 04112101 04120101 04122101 04000101 04002101 — Device fails to start or fails to boot — Creality Falcon, Creality Creality Falcon T1 control firmware (8-digit fault codes)
- 01001005 01001606 01001608 01001609 01001615 01001618 01001046 01001611 01001055 — Device reset/home failed — Creality Falcon, Creality Creality Falcon T1 control firmware (8-digit fault codes)
- 01001601 01001603 01001611 01001056 01001055 — The device prompts "Needs to be homed" or the position is lost — Creality Falcon, Creality Creality Falcon T1 control firmware (8-digit fault codes)
- 01001302 01001305 01001306 01001307 09012008 09012009 09032001 — The file cannot be opened or fails to read — Creality Falcon, Creality Creality Falcon T1 control firmware (8-digit fault codes)
- 01001001 0100100 01001019 01001039 01001011 01001020 01001021 01001022 01001023 01001024 01001025 01001026 01001027 01001028 01001029 01001030 01001031 01001032 01001033 01001034 01001035 01001036 01001038 01001040 01001042 01001048 01001303 01001304 01001316 01001317 — Content error or format error occurred during file processing — Creality Falcon, Creality Creality Falcon T1 control firmware (8-digit fault codes)
- 01001306 01001308 01001307 01001314 01003301 01003302 01003303 01003304 09012015 09012016 09012017 09012018 — File interruption or timeout during processing — Creality Falcon, Creality Creality Falcon T1 control firmware (8-digit fault codes)
- 01001601 01001322 01001602 01001045 01001612 01001015 01001010 01003007 01001316 — Trigger Limit Alarm — Creality Falcon, Creality Creality Falcon T1 control firmware (8-digit fault codes)
- 01001318 04012002 07001001 — Flame Detection Alarm — Creality Falcon, Creality Creality Falcon T1 control firmware (8-digit fault codes)
- 04011004 04011020 04132002 04011021 04130001 — Device temperature is too high — Creality Falcon, Creality Creality Falcon T1 control firmware (8-digit fault codes)
- 04011000 04012202 01001320 04012006 04012008 04012009 04010202 04012201 04181002 04182003 01001323 07022120 07022122 — Laser module is abnormal — Creality Falcon, Creality Creality Falcon T1 control firmware (8-digit fault codes)
- 7022201 — Calibration anomaly — Creality Falcon, Creality Creality Falcon T1 control firmware (8-digit fault codes)
- M222 S23 — Access-control key exception — xTool, xTool xTool S1 machine firmware/controller